CLE / CLS Series Fiberglass Dispenser Sumps

PCI CLE / CLS Series Dispenser Sumps provide secondary containment beneath fuel dispensers, enclosing piping connections, penetration fittings, and shear valves with access for installation, inspection, and service.

A 100% corrosion-resistant fiberglass sump body and heavy-gauge steel frame provide a durable foundation. Conduitless entry, a nestable design, and multiple dispenser configurations simplify installation and handling.

Room for Multiple Product Entries

Extended sump walls provide room for up to five product entries on applicable models, accommodating multiple product lines beneath the dispenser.

Heavy-Gauge Steel Frame

The steel frame provides strength and rigidity and is designed to lock into the concrete foundation for secure dispenser mounting.

Single Conduitless Entry

Conduit can enter the bottom of the dispenser without penetrating the sump walls, reducing the number of penetration fittings and potential entry points for outside moisture.

Single-Piece Sump Body

The fiberglass body is constructed as a single piece, eliminating body seams and supporting dependable containment.

Duo-Molded Fiberglass Construction

PCI’s Duo-Molded Technology combines two layers of fiberglass with high glass content for strength and fuel resistance.

Brite-White Interior

PCI’s Brite-White interior reflects light for better visibility and helps identify leak points during inspection and service.

Universal Stabilizer Bars

Universal stabilizer bars provide three-axis adjustment to accommodate multiple product lines without displacing piping. The assembly supports proper load transfer during dispenser impact and is ordered separately.

Composite Rainlip

A 1-inch composite rainlip helps prevent surface runoff from entering the sump and resists rust and corrosion. Rainlip availability varies by model.

Nestable Design

Multiple sumps nest together to reduce shipping volume and warehouse space, helping lower freight costs and simplify inventory handling.

Factory Pre-Plumbed Options

Full and partial factory pre-plumbing are available to reduce field assembly and installation time. Each pre-plumbed sump is built to your specifications and hydrostatically and pressure tested before shipment.

Double Wall Options

Double wall models are available for installations requiring interstitial monitoring, with configurations supporting dry, vacuum, or fluid-filled monitoring. Required monitoring accessories are ordered separately.

DEF Configurations

For dispensers handling fuel and diesel exhaust fluid, PCI’s DEF Series offers a dual-compartment configuration.

Dispenser Compatibility

Models are available for Bennett, Gasboy, Gilbarco, and Wayne dispensers. Refer to the model specifications for dispenser fit, dimensions, and stabilizer kit requirements.

Specifications and Installation Resources

Download the product brochure and installation instructions for model dimensions, dispenser compatibility, component options, and installation requirements.

PCI fiberglass dispenser sumps provide dependable secondary containment, with versatile designs and factory pre-plumbed options that simplify installation.
PCI fiberglass dispenser sumps provide dependable secondary containment, with versatile designs and factory pre-plumbed options that simplify installation.

Standard Features

Duo-Molded Technology

Our fiberglass sumps utilizes Duo-Molded Technology. Using premium raw materials with a high glass content, we create two layers of fiberglass, offering superior strength and fuel resistance.

‘BRITE-WHITE’ INTERIOR

Our signature ‘Brite-White’ interior reflects light for better visibility and makes identifying leak points easier.

PCI 100% fiberglass sumps and fittings

100% Fiberglass

100% high-quality, non-corrosive fiberglass provides long-term reliable containment from fuel exposure without voiding warranty, warping, cracking or becoming brittle.

UNIVERSAL STABILIZER BARS

Universal stabilizer bars with 3-axis adjustment accommodate multi-product dispensers without displacing product lines and ensure proper load transfer in case of an impact from any direction.

SINGLE PIECE CONSTRUCTION

Constructed as a single piece which eliminates any seams, providing less places for water penetration.

1″ COMPOSITE RAINLIP

1″ Composite Rainlip protrudes from the bottom of the dispenser to prevent surface water from entering the sump. This also offers better protection against rust and corrosion than metallic rainlips.

Optional Features

Pre-Plumbed Service Available

PCI’s Dispenser Sumps are available with completely customizable pre-plumb service built to customer’s specifications. Our pre-plumb dispenser sumps include all internal piping from the shear valve to penetration, eliminating the need for any additional field labor.

Double Wall Options Available

Available in double wall for a variety of monitoring options to satisfy local regulations and requirements. From dry fluid or fluid filled interstitial to vacuum interstice monitoring, PCI has all options to best fit your installation and compliance needs.

Dimensions

Dispenser Single Wall Double Wall Width Length Stabilizer Kit
Bennett Pacific

CLE146390B

CLEDW146390B

14.75″ 39″ SVU-L
Bennett 3000 CLS120206 CLSDW120206 12″ 20.75″ SVU-S
Gasboy Atlas CLS120206A CLSDW120206A 12″ 20.75″ SVU-S
Gilbarco Encore CLE174375 CLEDW174375 17.5″ 37.5″ SVU-L
Gilbarco Legacy CLS120206X CLSDW120206X 12″ 20.75″ SVU-S
Wayne Century CLE154260 CLEDW154260 15.5″ 26″ SVU-L
Wayne Reliance CLS154260R CLSDW154260R 15.5″ 26″ SVU-L
Wayne Select CLS154260 CLSDW154260 15.5″ 26″ SVU-L
Wayne Ovation CLE146390 CLEDW146390 14.75″ 39″ SVU-L
Wayne Vista (UHC) HS3, HS4 CLS154294 CLSDW154294 15.5″ 29.5″ SVU-L
Wayne Vista 48″ CLS112376 CLSDW112376 11.25″ 37.5″ SVU-S
Wayne Helix 36″ CLS170260 CLSDW170260 17″ 26″ SVU-L
Wayne Helix 48″ CLE170365 CLEDW170365 17″ 36.625″ SVU-L

Additional Models Available

Additional Double Wall AcceSsories (ordered Separately)

Part No. Description
EQP-DW-VAC Vacuum Kit (Required for all Double Wall Sumps)
EQP-IF-5GAL Interstitial Fluid, 5 Gallons (Required for Double Wall Sumps with Fluid Filled Interstice)
EQP-IF-ADP-UC Interstitial Fluid Adapter Kit ( 1 Per Sump, Required for Double Wall Dispenser & Grade Level Transition Sumps with Fluid Filled Interstice)

To learn more about Double Wall Dispenser Sumps, Visit the Double Wall page »

CLE Sump Dimensions
CLE Dispenser Sump Dimensions

Downloads

Regulatory

UL® Listed 2447

California Code of Regulation Title 23, Division 3, Chapter 16, Section 2631 (AB 2481/ California VPH)

State of Floria Department of Environmental Protection Approved / Registered Storage Tank System: EQ-203

Installation Video